  • NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    779593-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • Millimeter-Wave Noise Source, R-band, 26.5 to 40 GHz

    R347B - Keysight Technologies

    The Keysight R347B noise source covers a 26.5 to 40 GHz frequency range. This waveguide noise source allows you to make accurate and convenient noise figure measurements on millimeter-wave devices. The R347B provides highly precise broadband noise at the input of the system or component under test. The noise figure meter then processes the ON/OFF ratio of noise power present in the system IF, and provides an accurate reading of noise figure and gain. The R347B noise source has remarkable ENR stability over time, which allows longer recalibration cycles and more accurate noise figure measurements.

  • Semi-Rigid Cable, 3.5 Mm (Test Port) To 3.5 Mm

    85131C - Keysight Technologies

    The Keysight 85131C is an 81 cm (32 in) long1 semi-rigid cable with a 3.5 mm female2-to-PSC-3.5 mm female connector. Cable frequency range is DC to 26.5 GHz with a return loss of 17 dB or better. Insertion loss is 0.43 * sqrt(f) + 0.3, where f is frequency in gigahertz, for the test port connector and 2.5 dB at maximum frequency for the device connector. Phase stability of the semi-rigid / flexible cables is specified with a 90-degree bend using a 4 to 3-inch radius. Stability1 of the 85131C is less than 0.06 dB, and phase is 0.16 * f + 0.5, where f is frequency in gigahertz.

  • 802.11ad Testbed, Reference Solution

    Keysight Technologies

    Generate and analyze 802.11ad fully coded PHY waveforms for complete component, subsystem, and system performance at baseband, IF, and millimeter-wave. This Reference Solution combines Keysight Technologies software and hardware to provide a flexible testbed for 802.11ad waveform generation and analysis. Software provides the flexibility to generate and analyze 802.11ad waveforms with a wide range of different attributes. Hardware provides the flexibility to support baseband, IF, and millimeter-wave test planes. Create waveform sequences with unique 802.11ad packet structures including Modulation Coding Scheme (MCS), packet length, payload data type, and interpacket gap length, etc.

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • Gas Filled Hv Test Transformer

    YDQW-50KVA/250KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Gas-Filled Hv Testing Transformer

    GTU-300KVA/600KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time. Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Inflatable High Voltage Testing Transformer

    GTU-250KVA/500KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • High Power, Low PIM Switch Unit

    LPSU - AWT Global

    Low PIM coaxial switch matrix 5 x 6 or 1 x 4 configurationFrequency range 698-2700 MHz.SCPI commands via Ethernet (wired or wireless).Significantly reduces test time for multi frequency PIM applications.Applications: ATE systems, multi-band antenna and component testing.

  • AC/DC Current Probes

    T3CP Series - Teledyne LeCroy

    Teledyne Test Tools AC/DC Current Probes are powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range of five current probes includes models with bandwidths up to 100 MHz, peak currents up to 500A and sensitivities to 1 mA/div.

  • Compact Goniophotometer

    LSG-1200A - Lisun Electronics Inc.

    The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System

  • DC Power Supplies

    XG 850 - AMETEK Programmable Power, Inc.

    The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.

  • PXIe Multiport Vector Network Analyzer, 1 MHz to 9 GHz

    M9485A - Keysight Technologies

    1 MHz to 9 GHzUp to 12-ports in one chassis, 24-ports in two chassis Various applications - full N-port cal, FOM, Pulse, time-domain, noise figure and gain compression analysis capability Improve accuracy, yield & margins with the best PXI VNA speed, dynamic range, trace noise and stability Improve throughput with fast cycle time: 5 msec at 201 points, 2-port calVarious configuration with standard test set and configurable test set

  • Battery and Alternator Analyser for 12V DC Systems

    1176 - Draper Tools Ltd

    Checks battery charge level and alternator output level. 880mm of insulated cable with test probe and earth (crocodile) clip. For 12V DC systems only. Display packed.Warning: For testing DC circuits on vehicles within the voltage range only. Not suitable for testing mains supply AC circuits.

  • Precision Resistor Module 18-Channel

    40-297-001 - Pickering Interfaces Ltd.

    A simple solution for applications requiring accurate simulation of resistive sensors. The 40-297 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems. It is particularly well suited to applications such as the testing of engine controllers where resistive sensors provide information on parameters such as temperature.